|
|
Things to remember when using this dashboard:
• Only Active SKUs are considered
• The fill rate is calculated for external demand only, it is not the total demand, which includes internal demand and external demand [view Fill Rate Calculation]
• Fill Rate Aggregation is performed at all levels, directly from the SKU to that level, for all dimension (Service Group, Part, Location, Time)
• External demand is identified for non bin locations using the External Forecast streams with demand streams that have the Use In Total field set to Y
• If an On Hand record is not available on the First Time demand date, a value of zero (0) On Hand for that day is used.
• If a Stock Level record is not available on the First Time demand date, the SKU will be treated as Non-ASL, and the Planned Fill Rate is zero (0)for that day.
• If an IO Stockable Status record is not available on the First Time demand date, the SKU is treated as Forced Non-Stock.
• If a SKU is not assigned to a Service Group or is not planned in Inventory Optimization, it does not appear in the Fill Rate dashboards. The SKU is displayed in the Fill Rate Analysis and Service Group Fill Rate Analysis dashboards once it is assigned to a Service Group and the IO stockable status is available.
|
|
Widget
|
Description
|
|---|---|
|
Service Group – Demand Missed Summary
|
Click a Service Group hyperlink to open the Service Group Fill Rate Detail dashboard, populated with the details for the SKUs associated with the selected service group.
|
|
Top 5 Service Groups by Highest Delta Fill Rate
|
Click a point on the line graph to open the pop-up menu and select HyperLink. Then select Service Group – Service Group to open the Service Group Fill Rate Detail dashboard
|
|
Top 5 Service Groups by Highest Missed
|
Click a point on the line graph to open the pop-up menu and select HyperLink. Then select Service Group – Service Group to open the Service Group Fill Rate Detail dashboard
|
|
System Level – Unit Fill Rate
|
Click a point on the line graph to open the pop-up menu and select HyperLink to refresh the Fill Rate Analysis dashboard with the data relative to the selected point.
|
|
System Level – SKU with Demand Missed Summary
|
Do any of the following:
• Select a Location hyperlink to open the Demand Miss Analysis dashboard, populated with the details for the location selected and Stockable filter setting.
• Select a Part Number hyperlink to open the Demand Miss Analysis dashboard is opened, populated with the details of the part number selected for the corresponding location and Stockable filter setting.
|
|
System Level – Location with Demand Missed Summary
|
Select a Location hyperlink to open the Demand Miss Analysis dashboard, populated with the details for the location selected and Stockable filter setting.
|
|
System Level – Part with Demand Missed Summary
|
Select a Part Number hyperlink to open the Demand Miss Analysis dashboard, populated with the details for the part number selected and Stockable filter setting.
|
|
System Level – Line Fill Rate
|
Click a point on the line graph to open the pop-up menu and select HyperLink to refresh the Fill Rate Analysis dashboard with the data relative to the selected point.
|
|
System Level – SKU with Lines Missed Summary
|
Do any of the following:
• Select a Location hyperlink to open the Demand Miss Analysis dashboard, populated with the details for the location selected and Stockable filter setting.
• Select a Part Number hyperlink to open the Demand Miss Analysis dashboard, populated with the details of the part number for the corresponding location and Stockable filter setting.
|
|
System Level – Location with Lines Missed Summary
|
Select a Location hyperlink to open the Demand Miss Analysis dashboard, populated with the details for the location selected and Stockable filter settings.
|
|
System Level – Part with Lines Missed Summary
|
Select a Part Number hyperlink to open the Demand Miss Analysis dashboard, populated with the details of the part number selected for the corresponding location and Stockable filter settings.
|